Sharper Images through Controlled Light Emission: How Nanoscopy Works

Science · Feature

Conventional light microscopy cannot distinguish closely neighbouring structures with unlimited precision. Super-resolution methods circumvent this limit by deliberately controlling the light emitted by labelled molecules. They do not violate any laws of optics. Their images, however, are produced under particular conditions — and initially show the distribution of the labels, not an unfiltered view of the entire cell.

The Limit Applies to a Particular Imaging Method

In a light microscope, a single luminous point appears not as a mathematical point, but as a spatially extended diffraction pattern. If two structures emitting light simultaneously are too close together, their patterns overlap. Conventional resolution is therefore limited by wavelength and optical geometry. Super-resolution fluorescence methods exploit an additional possibility: molecules do not all have to emit light simultaneously and in an unchanging way. In STED microscopy, excited fluorescence is selectively suppressed around a small central region. Other methods cause only a sparse selection of labels to emit light at any one time and determine their positions in succession. The information gained thus comes not solely from a sharper lens, but from controlled changes in the states of the dyes used, together with correspondingly adapted recording and analysis of the resulting light signals.

Localising Is Not the Same as Seeing Everything

The position of an isolated light-emitting molecule can be determined more precisely than the width of its diffraction pattern might initially suggest. To do this, many detected photons are analysed together. If enough molecules are localised in succession, a high-resolution map is produced. Yet this map is only as complete as the labelling and the sample. If dyes are missing at important locations, gaps remain. If the sample moves during image acquisition, structures can appear distorted. Repeated light emission from the same molecule can also affect interpretation. An impressively sharp image is therefore not yet proof of a particular biological organisation. Researchers need labelling controls, suitable reference samples and analyses that reveal possible artefacts. The achievable spatial accuracy must also be distinguished from the structural resolution actually demonstrated.

Living Cells Require Additional Compromises

With living samples, resolution, acquisition speed and gentle illumination are often in tension with one another. More light can provide additional information, but dyes bleach and cells can be adversely affected by the illumination. Longer acquisitions do not automatically improve the result if the structures under investigation change in the meantime. An experiment must therefore align its biological question with its timescale. It is established that controlled fluorescence makes spatial information accessible beyond the capabilities of conventional light microscopy. How reliably a particular protein pattern or a process involving motion is identified remains a question for the individual experiment. The developments honoured in 2014 have therefore not created a limitless window into the cell. They have opened up additional measurement possibilities whose strength becomes particularly apparent when limitations, labelling strategy and alternative explanations are explicitly taken into account.